Hot curing EPOGLASS-170

Epoglass 170 epoxy glue

Epoglass 170 is a hot-curing epoxy two-component adhesive designed for bonding ceramic, glass, metal, plastic, composite materials.

Quantity
18,00
min. 1

The temperature range of application of the hardened glue is -50 ... + 230 ° C, the glass transition temperature is 160 ... 170 ° C. Contains low boiling point solvent for easier application.

Main characteristics.

component A

epoxy resin 40 ... 45%

methyl acetate 55 ... 60% 

component B

hardener 8.5 ... 9%

methyl acetate 91 ... 91.5%

Mixing ratio of components, wt. h.

А:В = 3:1

Compressive strength, 23 оС, MPa

>60

Shore D hardness, 23 ° C

>80

Elastic modulus, 23 оС, GPa

3,5-3,8

Shear strength of the adhesive joint, aluminum to aluminum, 23 ° C, MPa

17

Application temperature range, оС

-50…+230

Glass transition temperature, оС

160…170

Volume electrical resistance, Ohm * cm

>1014

Curing mode:

80 оС, 1 h or 100 оС, 0,5 h

80 оС, 1 h plus 180 оС, 1 h

   - minimum

12 month

   - optimal

10 day

1 month

Preparation of surfaces for bonding.

The surfaces to be glued must be thoroughly cleaned of all kinds of dirt and dried before applying the glue. Smooth, glossy surfaces are recommended to be additionally abraded or etched.

Preparing the glue.

Before using the glue components, measure component A and component B in a 3: 1 ratio by weight, place in a clean glass or plastic container and mix thoroughly.

Glue application.

Epoglass 170 glue should be applied in a thin even layer with a brush to both bonding surfaces. On porous surfaces, it is recommended to apply 2-3 layers of glue with an interval of 5-10 minutes. The surfaces with the adhesive applied should be kept in air for at least 15 minutes for the solvent to evaporate. Then the surfaces to be glued are aligned and tightly and evenly pressed with a force of 1-5 kg ​​/ cm2, followed by heat treatment to cure the glue. Apply and dry the adhesive in a well-ventilated area. Removal of excess glue and rinsing of instruments can be carried out with ethyl acetate or acetone.

Curing of the adhesive.

The minimum curing temperature of the adhesive is 80 ° C. As the curing temperature rises, the duration of the procedure decreases. So, at 80 ° C it takes 1 hour, at 100 ° C - 30 minutes. The maximum characteristics of the glue are achieved during heat treatment at 80 ° C for 1 hour, followed by heat treatment at 180 ° C for 1 hour. The heat treatment time starts from the moment the glued components reach the specified temperature. It should be noted that the glue is highly fluid during the curing process, so excess glue must be removed.

Storage.

It is recommended to store the components of the glue in a hermetically sealed container in a dark place at a temperature of 18-23 ° C. The shelf life of the glue components is up to 12 months if the storage conditions are observed. The prepared glue is stored for 10 days. at 23 ° C and 1 month. at 2-6 ° C.

×